In-Situ LevelTROLL 700

 

Features

  • Rugged, all Titanium design
  • Flood proof
  • Easiest software
  • Open communications
  • Long lasting battery life
  • Great accuracy

In-Situ Product Links

 

Introducing the Level TROLL® 700... the next breakthrough for professional water level monitoring applications including single or multi-step aquifer testing, precision river gauging, tidal influence studies, wave characterization, geothermal research, storm-event monitoring and more!

The Level TROLL® 700 features a rugged, all-titanium construction that is TIG welded to eliminate o-ring seals, Twist-Lock connectors, an ultra-low power system that eliminates the need to change batteries, and it is only 18.3mm (0.72 in) in diameter making it perfect for 1-inch wells or observation tubing. The 700 series of the Level TROLL® offers new logging modes such as Linear, Linear Average, Event, True Logarithmic, Step Linear, and Fast Linear for complete customization. Additional benefits of the Level TROLL® 700 include “Pause” and “Re-Start” logging features, a larger memory (350,000+ data points), 0.25 sec sampling (4 samples per second), ability to store and manage up to 50 log files, user notes, advanced compensation settings, and more.

The Level TROLL® comes standard with RS-485 Modbus, SDI-12, and 4-20mA communication options. It can be operated using a PC or a RuggedReader® handheld and it can easily be connected to a SCADA or other online systems.

True Logarithmic sampling is commonly used for aquifer testing (pumping and slug tests) to collect a large volume of early-time drawdown data while minimizing the amount of data collected later on. A convenient new “Re-Start” feature makes multi-step pumping tests easy. When changing the rate of the pump to the next step, simply press the “Re-Start” button and the logarithmic sampling rate will re-start at the beginning collecting a log cycle within the same file! A single log file can be restarted as many times as needed. Other modes such at “Step Log” and “Fast Linear” provide additional monitoring flexibility.

True Logarithmic: Measurements are logged as fast as possible and gradually get further apart until they become linear.

Step Linear: Measurements are logged on multiple schedules with varying linear intervals.

Applications:

  • Multi-step aquifer testing
  • Slug tests
  • Pumping tests
  • Tidal influence & wave characterization
  • River, lake, stream gaging
  • Landslide & flood prevention
  • Stormwater monitoring
  • Flow measurements
  • Research, studies
  • Marine buoys
  • Water pumping management
  • Estuaries and coastal monitoring

Features & Benefits:

  • Ultra-rugged, all-titanium design – Perfect for fresh and marine water monitoring. No more worries about corrosion. Excellent for marine, brackish and acidic sites.
  • Super accurate sensors – record minute changes in water level and temperature.
  • TIG-welded seals – Prevents flooding of instrument.
  • Ultra-low power system guarantees 5 years or 2-million readings – Forget changing batteries or running out of power.
  • Uses external battery or line power – no worries about running out of power.
  • RS-485 MODBUS, SDI-12, and 4-20mA – provides for easy connections to existing and online systems
  • Twist-Lock connectors that “lock” tight – 100% reliability
  • Halogen-free cables (LSZH rated) – no worries of toxic fumes if submitted to fire
  • Sealed desiccant options – allow for barometric compensation for maximum accuracy while preventing water & humidity intrusion
  • Extend cables by simply adding additional segments – maximizes your investment and maintain flexibility with your unit.
  • -20 to 80ºC temperature range – useful for geothermal and hot spring research and monitoring
  • Easiest ever Win-Situ® software – get the data you need fast! Large, sizable display that’s easy to see from a distance.
  • Linear logging – perfect for long-term monitoring
  • Pause logging feature – Pause logging when removing a unit. Reinstall and restart where you left off!
  • Specify start and stop times for logging – collect the data you need up to the date you want and no more
  • Ability to “undelete” files from the unit – no worries of accidentally deleting your data.
  • Data saved by sites not files – collect and save information by site automatically. No need to transfer data later.
  • Easy-to-read memory and battery gauges – know exactly how much is left
  • Friendly Wizards guide every step – reduces complicated steps and the need for tedious manuals
  • Submersible ranges up to 351m / cable length up to 1200m – measure to the depth you need.
  • FCC and CE emission tested – prevents susceptibility to outside emission interference and transient electrical surges
  • Version, range, and manufacturing info printed on side of the unit – know the details of the unit without opening the software. Reduces accidental over pressuring

Level TROLL® 700 only features & benefits

  • Restart logarithmic sampling within the same file – Perform multi-step aquifer tests with ease!
  • New logging modes – Linear, Linear Average, Event, True Logarithmic, Step Log, Fast Linear. Log the way you want to!
  • Up to 50 logging files can be programmed in the Level TROLL®complete flexibility and new possibilities in logging
  • Takes samples as fast as 0.25 seconds (4 samples/sec) – perfect for earthquake detection and wave modeling
  • Up to 350,000 data points of memory (4MB) – reduces the interval between data collection

 

Specifications    
General:    
Operating temperature range   -20 to 80C
Dimensions   18.3 mm (0.72 in) OD, 21.6cm (8.5 in) long
Weight (includes hanger)   0.197 kg (0.43 lb)
Output options   Modbus (RS-485/232), SDI-12, 4-20mA
Housing material   Titanium
Nose cone material   Black Delrin®
   
Power    
Internal battery   3.6V Lithium
Typical life*   5 yrs or 2-million readings
External power   8-36VDC
    *Whichever comes first. See battery guide for details.
   
Logging    
Memory / data points**   4 MB / 350,000+
Logging Rate   User selectable from 0.25 sec -- 49 days
Modbus   0.5 sec
SDI-12   0.5 sec
Measurement Types   Linear, Linear Average, Event, True Logarithmic, Step Log, Fast Linear
    **data point = time and date plus one parameter logged
   
Level Sensor   Silicon strain gauge
Type   Vented
Material   Titanium
Accuracy, FS***   +/-0.05% (15C)
FS = Full Scale   +/-0.1% (-5 to 50C)
    +/-0.25% (-20 to -5C & 50 to 80C)
    *** Accuracy with 4-20mA output option: +/-0.25% typical
Resolution   0.005% FS or better
Range   Vented:
  • 3.5 m, 11.5 ft (34.4 kPa, 5 psi)
  • 11 m, 35 ft (103.4 kPa, 15 psi)
  • 21 m, 69 ft (206.8 kPa, 30 psi)
  • 70 m, 231 ft (689.5 kPa, 100 psi)
  • 211 m, 692 ft (2068 kPa, 300 psi)
  • 351 m, 1153 ft (3446 kPa, 500 psi)
    Non-vented:
  • 10.9 m, 35.8 ft (206.8 kPa, 30 psi)
  • 60.1 m, 197.3 ft (689.5 kPa, 100 psi)
  • 200.7 m, 658.7 ft (2068 kPa, 300 psi)
  • 341.3 m, 1120 ft (3446 kPa, 500 psi)
   
Temperature Sensor    
Material   Silicon
Accuracy   +/-0.1C
Resolution   0.01C or better
Range   -20 to 80C
   
RuggedCable® with Twist-Lock Connectors    
Connector*   Twist-Lock connector OR stripped & tinned wire
Number of conductors   6
Internal Conductor Material   Polypropylene
Diameter 6.7mm (0.265 in)   Break strength 127 kg (280 lbs)
Bend Radius   2X diameter of cable = 13.72mm / 0.54 in
     
Cable Types:    
    Vented or Non-Vented Polyurethane
    Vented or Non-Vented Halogen-Free Polyurethane - LSZH rated
    Vented FEP (Generic Teflon®)
   

Minimum System Requirements: 400MHz Pentium® II, 128MB RAM, 100MB free disk space, Internet Explorer® 5.0 or higher, Windows® 2000 Professional SP2 or better

 

 

 

 

 

Price Request Form
Select the items for which you'd like a price by checking the boxes, then fill in your contact details and submit the form

 

Vented / Gauged LevelTROLL 700
Qty:     Level TROLL 700 with vented/gauged sensor
Vented Cable Options
Length      
Cable Type Polyurethane vented
  Polyurethane Halogen-Free vented
  FEP (Generic Teflon) vented
Cable termination   Rugged Twist-Lock Connection
   Stripped and Tinned use when wiring to external devices only)
Communication
 USB Cable Connect
  RS-232 Cable Connect
  RuggedReader PDA
     
Absolute / Non-Vented LevelTROLL 700
     
Qty:    Level TROLL 700 with absolute/non-vented sensor
Qty:    Twist-Lock Backshell / Hanger for absolute/non-vented sensor
Qty:    BaroTROLL - 1.14 bar (16.5 psi) (includes backshell hanger)
Cable Options
Length      
Cable Type Polyurethane non-vented
  Polyurethane Halogen-Free non-vented
   Suspension Wire - Stainless Polyurethane Coated Wire
        with 4 clamps (custom lengths only) 
   Stainless steel cable
Cable termination  Rugged Twist-Lock Connection
   Stripped and Tinned use when wiring to external devices only)
Communication
 USB Direct Connect
  RS-232 Direct Connect
  RuggedReader PDA
Accessories for all LevelTROLLs
 50mm (2") Well Dock  GPL050 Grip n lock cap 50mm wells
  100mm (4") Well Dock   GPL100 Grip n lock cap 100mm wells