In-Situ TROLL 9500

Multi-Parameter Water Quality

Features

  • Quick calibrations
  • Corrosion-resistant
  • Easiest software
  • Twist-Lock connectors
  • Long lasting battery life
  • Best accuracy

Related to this product:

In-Situ Product Links

Accurate, reliable, easy to use and affordable. Great for monitoring fresh waters, waste waters or marine waters...

Lower cost of Ownership
The TROLL 9500 saves time and money with convenient features like Quick-Calibrations, automated Low-Flow sampling, field-replaceable sensors, long-lasting internal power, and more.
Our field-proven Optical D.O. sensor (RDO™) reduces maintenance and the need to visit the site.

Higher Reliability
The TROLL 9500 features a corrosion-resistant housing that is suitable for fresh, waste and marine waters. The battery compartment and cable connector are IP67 rated even when detached. Sensors are field replaceable for easy maintenance and calibration.

Proven Accuracy
A factory report using NIST-traceable standards where applicable is included with each unit. Rigorous, independent 3rd-party validation proves our Optical D.O. (RDO) is the most accurate and rugged sensor in the industry. Ask us for a free report!

Easy Operation
The TROLL 9500 features innovations like Quick-Cal solutions, Twist-Lock connectors, and user-friendly software that make your job easier.

Features:
  • Easy to change batteries (2 x D-cells) with an IP67 rated waterproof battery compartment.
  • Proven reliable Twist-Lock connectors with fully detachable custom cable lengths. Also extendable!
  • Maximum flexibility - up to 4 field replaceable sensors all in less than a 4.7cm diameter.
  • Save time and money by using Quick-Cal solutions to validate or calibrate in less than 5 minutes.
  • Certified traceability to NIST standards where applicable. A calibration report is included.
  • Improve your data quality with the rugged and accurate RDO optical DO sensor.

TROLL 9500 Versions:
  • LTS stands for “Level, Temperature, and one additional Sensor” such as conductivity, pH, or dissolved oxygen.
    This version also includes internal data logging. It can be used for coastal applications or to measure ground water quality over time.
  • Profiler; Ideal for water quality sampling or profiling. The Profiler allows for any of the key water parameters such as pH, ORP, D.O., conductivity/salinity, temperature, depth. Memory is not included, but data can be logged to a
    RuggedReader or a PC.
  • The Profiler XP offers the same features as the ‘Profiler’ unit, but with the option to use XP or “Extended
    Parameter” sensors, such as turbidity, ammonium, nitrate, and chloride.
  • Professional; This version offers the highest value for most applications allowing for all the key parameters similar to the ‘Profiler’ PLUS internal data logging for recording trends over time.
  • Professional XP; The most capable TROLL 9500 that
    offers the same features as the ‘Professional’ unit, but with the option to use XP or “Extended Parameter” sensors, such as turbidity, ammonium, nitrate, and chloride.

Easy-to-change batteries with an IP67-rated waterproof battery compartment

  • IP67-rated, waterproof battery compartment
  • Battery compartment is vented to prevent an accidental explosion due to degassing batteries

 

Twist-Lock Connectors and Cable ExtenderProven, Reliable RuggedCable® System with Twist-Lock Connectors
  • Twist-Lock connectors make changing cables easy. Twist on and lock tight. No tools required.
  • Available in custom lengths up to 1212 m (4000 ft)
  • 136 kg (300 lbs) break strength
  • RuggedCable system available with polyurethane or Tefzel® jacket
  • Includes a Kellems® grip and desiccant
  • Twist-Lock connectors feature an all titanium construction and a two-year warranty
  • Cable extenders connect multiple cable lengths
Anatomy of a Twist-Lock Connector

Twist-Lock Cables

Compact Sensor Configurations
Use the TROLL® 9500 for profiling, surveying, and monitoring. It features the most sensors in a 1.85-inch (4.7-cm) housing with 5 sensor ports plus temperature and barometric pressure sensors. The compact design allows for all of the standard parameters such as DO, conductivity, pH/ORP, temperature, turbidity, level or measure, and an additional ISE parameter like nitrate, chloride, or ammonium.

 

 

Sub-2 inch TROLL 9500 with RDO® Optical DO Sensor

Use the RDO direct connect unit with all models of the TROLL 9500. For sub-2 inch configurations, turbidity and/or pressure cannot be used.

Port 1 = pH, pH/ORP, or ISE (XP units)
Port 2 = RDO sensor
Port 3 = RDO sensor
Port 4 = Conductivity (high or low)
Port 5 = Plugged

Sub-4 inch TROLL 9500 with RDO Optical DO Sensor

Use the RDO cable connect unit with all models of the TROLL 9500. Any TROLL 9500 with turbidity, pressure, or both must use a sub-4 inch configuration with adapter.

Port 1 = RDO sensor, pH, pH/ORP,
or ISE (XP units)
Port 2 = ISE (XP units)
Port 3 = RDO sensor, pH, pH/ORP,
or wiper
Port 4 = Conductivity (high or low)
Port 5 = Turbidity (XP units), pressure,
or both

Sensor Technologies

Sensor Accuracy Accuracy Range Response Time (T90) Methodology
Standard Sensors        
Barometric Pressure +/-0.3% FS 0-16.5 PSIA < 30 sec per 30 m (100 ft) cable Silicon strain gauge
Conductivity, low +/-0.5% or 2 µS/cm 5-20,000 µS/cm Instantaneous Std. Mthds. 2510, EPA 120.1
Conductivity, high +/-0.5% + 2 µS/cm 150-112,000 µS/cm1 Instantaneous Std. Mthds. 2510, EPA 120.1
DO (polarographic) +/-0.2 mg/L 0-20 mg/L, 0-200% saturation1 1-mil membrane:
1-2 min @ 25°C
2-mil membrane:
90 sec - 3 min
Std. Mthds. 4500-O G, EPA 360.1
DO (optical, RDO®) +/-0.1 mg/L
+/-0.2 mg/L
0-8 mg/L
8-20 mg/L1
30 sec ASTM D888-05, Test Method C
pH +/-0.1 pH unit 0-12 pH units < 15 sec, pH 7 to pH 4 Std. Mthds. 4500-H+, EPA 150.2
pH/ORP +/-5.0 mV +/-1400 mV < 15 sec Std. Mthds. 2580
Pressure +/-0.1% FS 0-15 PSI
0-30 PSI
0-100 PSI
0-300 PSI
In thermal equilibrium: Instantaneous
In thermal change:
♦ Instantaneous to +/-2% FS
♦ 30-60 min to +/-0.1% FS
♦ 1.5-2 hrs to +/-0.05% FS
Silicon strain gauge (vented or absolute)
Temperature +/-0.1°C -5°C-50°C < 30 sec EPA 170.1
XP Sensors        
Ammonium (NH4+) +/-10%2 0.14-14,000 ppm 3 N < 60 sec (T98), 1.4-14 ppm Std. Mthds. 4500-NH3 D4
Chloride (Cl-) +/-15%2 0.35-35,500 ppm 3 CL- < 60 sec (T98), 3.54-35.45 ppm Std. Mthds. 4500-Cl D4
Nitrate (NO3-) +/-10%2 0.14-14,000 ppm 3 N < 60 sec (T98), 1.4-14 ppm Std. Mthds. 4500-NO3 D4
Turbidity +/-5% or 2 NTU 0-2000 NTU Instantaneous (5 sec for first reading) ISO 7027

1 Full operating range 70 µS/cm – 200,000 µS/cm; typical accuracy from 70 to 150 µS/cm and from 112,000 to 200,000 µS/cm; ±2% + 4 µS/cm
2 When calibrated at ionic strength and temperature matching the sample, and in the absence of interferences; field use may deliver qualitative performance
3 Response range
4 Laboratory method requiring adjustment of pH and total ionic strength of water sample

RDO® Optical Disolved Oxygen Sensor

Using the latest technology to measure dissolved oxygen, the next generation In-Situ® RDO® optical dissolved oxygen sensor offers several advantages for long-term and ambient water quality monitoring.

  • Rugged design – Wiper-free sensor excels in demanding environments. Abrasion-resistant foil withstands fouling, high sediment loads, and rapid flow rates.
  • Automatic setup – RDO sensor cap with pre-loaded calibration coefficients simplifies set up and eliminates user programming errors.
  • Fast response – Ideal for vertical profiling and dynamically changing conditions.

 


Turbidity Sensor Follows ISO 7027 Standard

  • Patented micro focusing lenses
  • 0 to 2000 NTU
  • Uses Method ISO 7027
  • Multi-channel auto ranging
  • Automatic ambient light rejection
  • Optional wiper

NIST® Traceability
A calibration report is included with every unit ensuring traceability to NIST standards where applicable.


Win-Situ® 4 Software
Win-Situ® 4 software for the PC sets the standard for ease-of-use. Wizards guide every step from instrument set up to calibration and data logging. View data as a graph or report and easily export data to Excel®.

Profiler view displays real-time data in a meter or graphical format. Flow-Sense software helps automate low-flow sampling events and final report generation.

  • Integrated graphing and reporting
  • Powerful real-time display - Graph or meter views
  • Instant "one-click" export to Excel®
  • Quick-Calibration Wizard
  • View up to four graphs simultaneously - Select primary and secondary axis
  • Customize your view - Zoom tool, full or split screen, unit selection, and more!
  • Included FREE with purchase of TROLL® 9500 instrument
Win-Situ ® software
Win-Situ® 4 software - Graph view
Pocket-Situ 4 Software
View and log data with a RuggedReader® handheld PC. This IP67-rated handheld PC automatically synchronizes data with your PC when used with Pocket-Situ 4 software. View and download data real-time, start and stop logging operations, take voice notes, manage your schedule, save contacts, and more.

Automatically synchronizes data files to the PC

  • Powerful instrument controller
  • All of the features of Win-Situ® 4 software
  • View data in Graph or Meter format
  • View data real-time
  • Download data, calibrate sensors, set up logging
  • Fully functional PDA
  • GPS, Bluetooth®, and Wi-Fi® compatible
  • Use Pocket Word, Excel®, etc.
  • Read more about Pocket-Situ 4 software
  • Read more about the RuggedReader® handheld PC

 

 

Ordering Information / Price Request Form
Select the items for which you'd like a price by checking the boxes, then fill in your contact details and submit the form
Version  

TROLL 9500 LTS (sampling/profiling & logging)

TROLL 9500 Profiler (sampling/profiling)

TROLL 9500 Profiler XP (sampling/profiling with extended parameters)

TROLL 9500 Professional (as per Profiler plus internal logging)

TROLL 9500 Professional XP (as per Profiler XP plus internal logging)

Parameters            
Note: temperature and barometric pressure are included. Barometric pressure requires vented cable.
pH ORP DO Clarke Cell RDO - Optical DO      
Conductivity Low range Conductivity High range Depth (gauged/vented) Depth (absolute/non-vented)      
Extended Parameters
Turbidity Nitrate Ammonium Chloride  
         
Twist-Lock Cable      
Length 1m 5m

provide a per metre price

Custom length (1200m max)

Type vented/gauged non-vented/absolute
Material polyurethane FEP Halogen-Free polyurethane  
   
Other Options
 RuggedReader PDA
 Low Flow Sampling System
Other Option
     
Name*  
Company
Address line 1
Address line 2
City*
State
Post Code / Zip
Country*
Phone
Email*
Please tells us in a few words, about your application
     
   

 

 

 


Privacy | Disclaimer | Trademarks | Contact