QED MicroPurge® basicsTM MP20 Flow Cell

Simple, economical purge monitoring with automatic stabilization alert.

Water Quality Measuring with Integral Flow Cell and Automated Purge ScanTM Technology -- Purge Scan tells you when the water quality parameters have stabilised.

Monitor up to 5 parameters (pH, ORP, DO, Conductivity/Salinity, Temperature) while purging or sampling a well with the MP20 Flow cell system. New Purge Scan technology allows you to sample with confidence thanks to visible & audible stabilisation alerts.
The MP20 meter is designed expressly to simplify calibration and operation in the field, by eliminating non-essential features. It displays all readings automatically and is lightweight and water-proof.

 

MicroPurge Menu

MicroPurge basics components
MP10 Controller
MP40 Compressor
MP15 Power & Control Pack
MP20 Flow Cell
MP30 Drawdown Meter
Well Wizard Bladder Pumps
QED Sample Pro

Micropurge / Low-Flow Sampling Resource Page 
Low-Flow Procedure with QED basics equipment (456kb)
Portable MicroPurge® Sampling Equipment Catalog - 916kb 

Sales Index
Groundwater Pumps Index
 

Landfill Monitoring Products
  
Groundwater Sampling Products

The sonde is a compact, low-profile design with rugged, easy-to-service probes. The flow cell is designed to collect and vent gas bubbles effectively, and to distribute purge flow evenly for quick measurement response and more accurate readings. The enclosure is of the Sealed Type, meaning that the sample does not come into contact with air. The whole package is protected by a 3-year warranty, backed by service and support from QED, the leader in low-flow sampling.

Until now, deciding when stabilization had been achieved was complex, requiring you to monitor multiple parameters and make repeated calculations. The new MP20 Flow Cell simplifies this part of the process. Microprocessor-based PurgeScanTM technology performs the monitoring and calculation, clearly signaling when stabilization has occurred. This allows sampling to begin only when the pump discharges samples representative of the formation water.
 
Quick, precise measurements make low-flow sampling easy. The MP20 assures the user of collecting the most accurate samples, and save time and money on a groundwater sampling program. It also stores key data automatically, along with elapsed time of purging.
System Specifications:
Model No. MP20
Dimensions 18.5"x15"x6.5"  (47x38x17 cm)
Weight 14 lbs (6.4 kg)
Storage 100 Data Points
Stabilization Purge ScanTM  Technology (patent pending)
Case Material Structural Resin
Keypad 5 Keys

Meter Specifications:
Display 3.5" (9 cm)
Weight 2.1 lbs (1 kg)
Memory 100 Data Frames
Rating Waterproof NEMA 6 [IP67]
Power 3 "C" batteries
Battery Life 12 Hours
Temperature 23 - 122°F (-5 - 50°C)
Cable 6 foot (1.83 m)

Flow Cell Specifications:
Volume 175 ml
Material Rigid urethane
Fitting Type Soft-tube "clamp-free"
Fitting Size(s) Inlet: 1/4" I.D. x 3/8" O.D.     Outlet: 3/8" I.D. x 1/2" O.D.
Venting Modes Horizontal and Vertical
Sonde Connection Bayonet-style Twist Mount

Sonde Specifications:
Size 3"x9" (8x23 cm)
Weight 1.3 lbs (0.6 kg)

Typical Sensor Performance Specifications:
Range Accuracy Resolution
Temperature -5 - 50°C (23 - 122°F) ± 0.20°C (0.36°F) 0.01°C (0.018°F)
DO 0 to 20 mg/l ± 0.2 mg/l 0.01 mg/l
Specific Cond. 0-100 mS/cm ±1% of reading ± 1 count 4 Digits
pH 0 to 14 units ± 0.2 units 0.01 units
ORP -999 to 999 mV ± 20 mV 1 mV
Salinity* 0 to 70 PSS ± 1 count 0.01 PSS
*Calculated  

PurgeScanTM Specifications:
Parameter Stabilization range criteria



pH - +/- .2 units
DO - +/- 0.2 mg/l
Conductivity- +/- 0.020 m S/cm
ORP- +/- 20 millivolts
Stabilization basis




3 consecutive readings of selected parameters (one or more of above 4) within above limits, at time interval selected, from 1 to 9 minutes. For example, if 2 minutes is selected, then stabilization would be signaled when 3 consecutive 2-minute intervals showed in-range readings at the end of each interval, requiring 6 minutes.
Elapsed time since Purge Scan initiated shows at the bottom of the screen.
Full data sets are stored at time 0, every 5 minutes, and the 3 consecutive readings which satisfy the stabilization criteria.
 